Call Us: +44 (0) 1782 592900
Security Doors & Fire Doors

Certification

1. Fire Exit Doors 6. Endurance Testing
2. Fire Doors 7. Environmental Testing
3. Security Doors 8. Thermal Testing
4. Blast Doors 9. Hardware Standards
5. Acoustic Doors 10. CE Marking

 

1. Fire Exit Doors

Robust have had third party testing carried out to certify that our Fire Exit Doors, when fitted with panic exit devices, meet the criteria for panic devices according to the requirements of BS EN 179:1998 and BS EN 1125:1997.

2. Fire Doors

Robust Fire Doors have been tested to and passed the following standards:

Integrity Only to E240, in mild and stainless steel to:

  • BS 476-20: 1987 & BS 476-22: 1987
  • BS EN 1634-1:2000

Integrity / Partial Insulation to A60, in mild steel to:

  • IMO A.754(18)

In addition, the manufacture and supply of Robust Fire Doors is third party certified under Warrington Fire 'Certifire' certification scheme (Certificate No: CF61).

3. Security Doors

Robust Security Doors have been tested to and passed BS EN 1627:2011 and are available in a variety of LPS 1175 security ratings from SR2 to SR4 (Certificate No: 1070a).

  • Products attack tested to LPS 1175 SR2 standard provide up to 3 minutes of resistance to opportunist attempts at forced entry of protected premises using a range of mechanical tools including: screwdriver, levers, spanner, bolt cutters, claw hammer, drill, shears, etc.
  • Products attack tested to LPS 1175 SR3 standard provide up to 5 minutes of resistance to determined attempts at forced entry of protected premises using a wide range of tools including: cordless tools, short axe, cold chisels, crow bar, brick bolsters, gas torch, etc.
  • Products attack tested to LPS 1175 SR4 standard provide up to 10 minutes of resistance to experienced attempts at forced entry using a wide range of tools including: high powered cordless tools, felling axe, sledgehammer, power drill, disc grinder, jigsaw, etc.

Our Security Doors have also been tested to and passed Warrington Exova Certisecure STS 202 standard:

http://www.warringtoncertification.com/technical-information/3/sts202-april_2010_iss1.pdf

Robust Security Doors, in both personnel access and fire escape designs, are also included in the 'Secured by Design' scheme. Secured by Design is the official UK Police initiative to 'design out crime' and covers not only doors but also windows, gates, etc. To satisfy this standard, all products must be PAS 24 approved.

To find out more information about the 'Secured by Design' scheme, follow the link below:

http://www.securedbydesign.com/

To find out more information about Robust's 'Secured by Design' certification, follow the link below:

http://www.securedbydesign.com/members/robust-uk-limited/

Robust Security Doors have also been tested to European Security Standard DD ENV 1627:1999.

For specification advice and hardware specifications, please contact the sales office on +44 (0)1782 592900.

4. Blast Doors

Robust SD4 Security Doors have been tested to and passed EXR2 and EXR3 of the BS EN 13124-2:2004 (Explosion Resistance) standard.

5. Acoustic Doors

Robust Acoustic Doors have been tested to and passed BS EN ISO 140-3:1995.

The performance of Robust Acoustic Doors is described as the 'Sound Reduction Index' and is shown as a figure in dBs. It is a weighted average over a range of frequencies prescribed in the BS EN ISO 140-3:1995 standard.

Type dBs Performance Description
OUTA-DOR  22  Minimal Speech clearly audible
OUTA-DOR  25  Average
Normal speech understood
AC35 **  35  Good Loud speech audible but not intelligible
AC45 **  45  Very Good Loud speech just detectable
AC50 **  50  Excellent Loud speech barely audible

* Standard general purpose door
** Specific acoustic door

6. Endurance Testing

Our doors have recently undergone cycle testing to enable the doorset to be CE marked in accordance with UK legislation. Robust UK are one of the first manufacturers in the UK able to fully CE mark our doorsets in accordance with BS EN 14351-1:2006 Windows & Pedestrian Doorsets (External).

The opening and closing cycles of our doors have been tested to and passed Class 7 (500,000 cycles) of BS EN 1191:2000.

7. Environmental Testing

Our doors have undergone testing to prove their suitability for use for expected UK weather conditions to BS 6375-1: 2004 Weather Tightness, which incorporates specific tests for:

Air Permeability to: BS EN 1026:2000
Water Tightness to: BS EN 1027:2000
Resistance to Wind Loading to: BS EN 12211:2000

8. Thermal Testing

In line with current industry standards, Robust have had our doors tested as an installed product to BS EN ISO 10077-2:2003 (Calculations for Thermal Transmission of Window Framing Members) and we are also able to offer a cross-section material calculation rate.

9. Hardware Standards

In order to continue to provide quality products, Robust ensure that, where available, the hardware we use is regularly tested to the relevant European standards, in particular:

Hinges to: BS EN 1935:2002
Cylinders to:
BS EN 1303:2005
Door Closers to:
BS EN 1154:1997
Locks and Latches to:
BS EN 12209:2003
Lever Furniture to: BS EN 1906:2002

10. CE Marking

Robust are leading the field in our ability to provide full CE marking for our full range of steel doors in accordance with BS EN 14351-1:2006 Windows & Pedestrian Doorsets (External). This legislation requires that manufacturers of non-fire industrial doors apply the CE mark on their products because they are covered by a harmonised standard under the new Construction Products Regulation.