Robust UK Ltd Brook House Way Brookhouse Industrial Estate
Tel: +44 (1538) 752600 Fax: +44 (1538) 752604 
robust doors, fire doors, security doors, acoustic doors, blast doors, acoustic doors


Certification / Testing

Fire Exit Doors
Fire Doors
Installation of Fire Doors
Security Doors
Blast Doors
Acoustic Doors
Endurance Testing
Environmental Performance Testing
Hardware Standards


Fire Exit Doors

Robust have had third party testing carried out to show that our fire escape doors, when fitted with panic exit devices meet the criteria for panic devices according to the requirements BSEN 179 & BSEN1125 Test carried out to EN1204-6-2000 Ability to Release:


Fire Doors

Fire Doors have been tested to:

Integrity only up to E240, in mild and stainless steel to:

• BS476 part 22 1987
• BS EN 1634-1 2000

Integrity/ partial insulation to A60 in mild steel to:

• IMO A754/ 18

and their manufacture and supply is third party certified under Warrington Fire “Certifire” certification scheme.

Certificate No: CF618


Installation of Fire Doors

Robust are certified under the FIRAS scheme for the installation of steel fire doors. Certificate No: WC7135


Security Doors

Security Doors are currently being tested to ENV 1627. Doors are available in a variety of levels from SD2 – SD5


Blast Doors

Robust SD4 & SD5 Security doors have also been tested to BS EN 13124-2 Explosion Resistance, EXR2 & EXR3


Acoustic Doors

Acoustic Doors have been tested to BS EN ISO 140-3: 1995


Endurance Testing

Our doors have recently undergone cycle testing to enable the doorset to be CE marked. Robust UK expect to be one of the first manufacturers in the UK able to fully CE mark our doorsets in line with BSEN14351 Windows & Pedestrian Doorsets (External)

Opening & closing cycles EN1191-2000 tested to class 7 (500,000 operations)


Environmental Performance Testing

Our doors have recently undergone testing to prove their suitability for use for expected UK weather conditions to BS6375 part 1 2004 Weather Tightness which incorporates specific tests for :

• Air Permeability, to BSEN1026: 2000
• Water Tightness, to BSEN1027
• Resistance to Wind Loading, to BSEN12211:2000

Thermal testing: In line with current industry standards Robust have had our doors tested as an installed product to:

BSEN ISO..10077-2 2003 Calculations for Thermal Transmission of Window Framing Members and are also able to offer a cross section material calculation rate.


Hardware Standards

To ensure quality products Robust ensure that where available the hardware we use is tested to the relevant European standards, namely:

• Hinges to: BSEN1935
• Cylinders to: BSEN1303
• Door Closers to :BSEN1154
• Locks and Latches to:BSEN12209
• Lever Furniture to:BS1906-2002